Bowie and Dick Test, Bd Test Pack, Bowie Dick Test Pack manufacturer / supplier in China, offering Bowie and Dick Bd Test Pack for Autoclave Sterilization, Tracheostomy Tube, Anaesthesia Mask and so on.

(/ )

Supplier Homepage Product Medical consumables Bowie and Dick Bd Test Pack for Autoclave Sterilization

Bowie and Dick Bd Test Pack for Autoclave Sterilization

FOB Price: US $0.7 / Piece
Min. Order: 10,000 Pieces
Min. Order FOB Price
10,000 Pieces US $0.7/ Piece
Get Latest Price
Port: Shanghai, China
Production Capacity: 125×125×16
Payment Terms: L/C, T/T, Western Union, Paypal

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: SC AQJB
  • Material: Non-woven Fabric
  • Ethylene Oxide Sterilization: Without Ethylene Oxide Sterilization
  • Group: Machine
  • OEM: Yes
  • Sterilization Method: Steam
  • Trademark: sc
  • Specification: 125× 125× 16
  • HS Code: 4823909000
  • Type: Surgical Supplies Materials
  • Certification: CE, FDA
  • Quality Guarantee Period: Two Years
  • Logo Printing: With Logo Printing
  • Pack: 100bags/Carton
  • Operation Condition: 134 ;C, 3.5minutes
  • Transport Package: Carton
  • Origin: China
Product Description
Bowie Dick Test Pack makes the operator a right control of the autoclave and verify possible defects during Bowie Dick's cycle. Bowie-Dick test packs should be used daily, especially after a sterilizer is installed, relocated, after sterilizer malfunction, after sterilization process failures, and after any major repairs of the sterilizer.
Operation Condition:  134ºC, 3.5minutes
Single use Bowie Dick pack is characterized by the most reliable test such as: 
1. Point out the presence of air leaks in the autoclave immediately and accurately; 
2. Nontoxic ink and completely recycled materials;
3. Color Change: yellow to brown
4. CE certificated
5. Lead free 
Notices:
1. The saturated stream pressure should reach to 0.4Mpa - 0.6Mpa if air is supplied through pipe; and non-uniform color changes may be observed if the pressure is lower than 0.3Mpa;
2. As for the pre-vacuum steam sterilizers or high vacuum autoclave with pulsing systems with air supply by pipe, the time of stopping air supply should longer than 2 days; and air-removal process should be done before re-using, or else, large amount of aqueous vapor existing in saturated stream may cause difficulty in cool air removal and wet pack, which will result in incapability of demonstrating test results due to wet B-D test paper.

Size & Packaing:

 

CodeSize  L(mm) × W(mm) × H(mm)ConditionColor Change
BD1125×125×16134ºC 3.5minYellow-Black
BD2125×125×26134ºC 3.5min Yellow-Black
BD3125×125×30134ºC 3.5min Yellow-Black
BD1-1125×125×16121ºC 16.9minYellow-Black
BD2-1

125×125×26

121ºC 16.9min Yellow-Black
BD3-1125×125×30121ºC 16.9min Yellow-Black