Gold Member Since 2014
Audited Supplier
Sure Care Corporation

HIV Test Kit, HIV Test, Rapid Rota Test manufacturer / supplier in China, offering Rapid HIV I&II Test Kit, Disposable Vaginal Speculum (French Type), Digital ECG Machine with Single Three Six Twelve Channel (SC1103) and so on.

(/ )

Supplier Homepage Product Diagnostic Products Rapid HIV I&II Test Kit

Rapid HIV I&II Test Kit

Purchase Qty.:
(Pieces)
500-99,999 100,000+
FOB Unit Price: US $0.07 US $0.1
Purchase Qty. (Pieces) FOB Unit Price
500-99,999 US $0.07
100,000+ US $0.1
Get Latest Price
Port: Shanghai, China
Production Capacity: 50, 000, 000/Year
Payment Terms: L/C, T/T

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: SC-CXL001
  • Usage Mode: For external use
  • Type: Biological Diagnostic Reagents
  • Form: Strip
  • OEM: Yes
  • Deliver Date: Within 10days
  • Transport Package: Single Pack
  • Origin: China
  • Supply Tyle: OEM Service
  • Suitable for: Elderly, Children, Adult
  • Application: for Diagnosis
  • 1 Test/Pouch: 25tests/Kit
  • Sample: Free
  • Trademark: SURECARE
  • Specification: CE
  • HS Code: 3005
Product Description

   Specifications

 
Rapid HIV I&II Test: 
Specimen: whole blood/serum/plasma 
Format: cassette or strip 
Sensitivity: 99.6% 
Specificity: 99.7% 
 
 

For in vitro diagnostic use only

 

INTENDED USE

Rapid HIV I&II Test Card is a single use, rapid test device, double antigen sandwich immunoassay  for qualitative detection of antibodies to Human Immunodeficiency Viruses or HIV I&II in serum, plasma or whole blood. It is intended for medical institution as the aid for the diagnosis of possible HIV infection. The product may be used for the quick screening of blood donors and blood products.

 

 

PRINCIPLE

Rapid HIV I&II Test Card employs chromatographic lateral flow device in a cassette format. Colloidal gold conjugated recombinant antigens (Au-Ag) corresponding to HIV-1 gp120, gp41 and HIV-2 gp-36 are dry-immobilized at the end of nitrocellulose membrane strip. HIV 1+2 antigens are bond at the Test Zone (T) and rabbit anti-HIV 1+2 antibodies are bond at the Control Zone (C). When the sample is added, it migrates by capillary diffusion rehydrating the gold conjugate. If there are HIV1 or HIV 2 antibodies in sample, they will bind with the gold conjugated antigens forming particles. These particles will continue to migrate along the strip until the Test Zone (T) zone where they are captured by the HIV 1+2 antigens generating a visible red line. If there are no HIV 1 or HIV 2 antibodies in sample, no red line is formed in the Test Zone (T).The gold conjugate will continue to migrate alone until it is captured in the Control Zone(C) by the rabbit anti-HIV 1+2 antibodies aggregating in a red line, which indicates the validity of the test.

 

 

 

PROCEDURE

For  Test Strip

1. Bring all materials and specimens to room temperature.

2. Remove the test strip from the sealed foil pouch.

3. Label the test strip with specimen identity by writing the ID on the top label of the strip.

4. Place the test strip on a flat horizontal surface.

5. Using the transfer pipet to draw up the sample.

6. Hold the transfer pipet in a vertical position over the sample pad and dispense 2-3 drops (80-  120 ml) of sample onto the sample pad.

7. Read the result at 20 minutes after adding the sample.

For Test Card

 

1. Bring all materials and specimens to room temperature.

2. Remove the test card from the sealed foil pouch.

3. Label the test card with specimen identity.

4. Place the test card on a flat horizontal surface.

5. Dispense 2 drops (80-100mL) of sample into the specimen well S using the sample dropper   provided.

6. Read the result within 20 minutes. Reactive samples can be read as soon as distinct colored bands appear on both test zone and control zone. To confirm a negative result, please read the result at 20 minute after adding sample.

 

INTERPRETATION OF RESULTS

Reactive: Positive

If two colored bands are visible within 20 minutes, the test result is reactive or positive and valid. The test result can be read as soon as a distinct colored band appears in the test area.

Non-reactive: Negative

If test area has no color band and the control area displays a colored band, the result is non-reactive or negative and valid.

Invalid result:

The test result is invalid if a colored band does not form in the control region. The sample must be re-tested, using a new test device.

 

FEATURE:

1)        Simple: simply add specimen and dilution(if necessary) into sample well

2)        Rapid: results come out at 20 minutes

3)        Visually interpreted: don't need any equipment

4)        Stable: more than 12 month period of validity

 

 

PACKING

Cassette: 25 tests/box, 40tests/box
Strip: 50 tests/box, 100tests/box


Rapid HIV I&II Test Kit

Send your message to this supplier
Avatar
Mr. Leo Lee
Sales Manager
*From:
To: Mr. Leo Lee
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category