300tests /hour 24hours refrigeration auto washing 80 reagent positions 80 sample positions 81 reaction positions
Technical Feature Performance Type: Discrete Automatic Principle: Absorption Spectrometry, Turbidimetry Throughput: Constant 300tests/hour (without ISE) Test Method: End-point, Fixed-time(two point), kinetic, support double reagent and double wavelength Test Sequence: Run tests in strict accordance with sample sequence, Insert emergency at any time Online Sample: 80 samples/ batch, unlimited batch input Reaction Time: Max 15minutes Reaction Volume: Mini 150μl Cuvette: 81 cuvettes Optical System Light Source: Halogen-tungsten lamp, 12V/20W More than 2000hrs service time Spectrometric Method: After spectrometric method Wavelength: 8 -12wavelengths, selectable among 340-900nm Absorption Range: 0-4.0Abs Optical System: Integrated full closed optical system Sample system Sample Tray: 80 positions, independent disk Sample Volume: 2-100μl, 0.1μl by step, Sample Probe: Polishing for both interior and exterior, Liquid level detection, anti-collision protection and inventory checking; probe with special cleaning solution to prevent contamination Mixing System: Separate mixer, mix the sample and reagent completely Others Water Consumption: less than 10L/hour Power Supply: AC 220 ±22V 50HZ ±1HZ Power: Max 550VA Ambient Temperature: 15°C-30°C Reagent System Reagent Volume: 20-500μl, 1μl by step Reaction Tray: 80 positions, open system, independent disk Reagent Probe: polishing for both interior and exterior, Liquid level detection, anti-collision protection and inventory checking, have automatic stop and alarm prompt for an obstacle Reagent open system,close system for option Temperature Control System Refrigeration System: water -medium uniform cooling technology Heating Time: less than 3minutes Reagent Tray Temperature: 2-10°C Reaction Temperature: 37±0.1°C Temperature Fluctuation: ± 0.1°C Calibration and QC Calibration Mode: Linear, Logit-4p, Logit-5p, Spline, Factor, Polynomial Automatically check calibration curve and fitting the best calibration curve QC Type: Multi-type QC Rules: Multi-rule; default: Westguard Status Monitoring: Real -time monitor the sample tray, reagent tray, reaction tray; Real-time display reaction temperature, reagent remain, reaction curve, calibration curve and QC chart. Inspection and Judgment: Reaction end point judgment, reaction linear range judgment, substrate depletion judgment, reagent blank absorbance judgment Operation Unit Operation System: Windows 2000, XP Database: SQL Server Data Storage: Automatic storage and backup, permanently preserve all kinds of data Print Content: Print content can be customized Print Format: Provide a variety of print format |
|
|