OLED/LCD Display Retail Blood Monitor Fingertip Pulse Oximeter

Product Details
Customization: Available
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Pulse Oximeter
Still deciding? Get samples of US$ 20/Piece
Request Sample
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500000 USD
Plant Area
1001~2000 square meters
  • OLED/LCD Display Retail Blood Monitor Fingertip Pulse Oximeter
  • OLED/LCD Display Retail Blood Monitor Fingertip Pulse Oximeter
Find Similar Products

Basic Info.

Model NO.
sc -YYQX001
Certification
CE
Group
All
Delivery
Based on Order Quantity,Commomly Within 20 Days
Package
100PCA/CTN
Transport Package
Carton
Specification
CE
Trademark
Surecare
Origin
China
HS Code
9018
Production Capacity
100000 PCS Per Day

Product Description

Fingertrip Pulse Oximeter

Specification

Model:YAD-002
Power:3V DC AAA(x2) 
Unit net weight :28.4g
Unit gross weight :44g
Packing size:84*57*36MM 
Small box weight:42PCS/small box 1.98KG 32*23*11CM
Big box weight:420PCS/big box  20.8KG 60*33.5*49CM
Product acessorie:s:User Manual * 1 Hanging rope * 1 Quality Control Card * 1
Instructions for Use:
1. Install a pair of AAA batteries into the battery box.
2. Insert your finger into the rubber hole of the oximeter.
3. Put your finger into the test position of the oximeter, and lightly press the button on the panel of the oximeter to automatically test the results within about 8 seconds.
4. When the oximeter is working, do not shake your fingers or move your body.
5. Press the touch button on the panel to adjust the direction of the display interface according to usage habits.
6. If there is no finger inserted, the device will automatically shut down within 8 seconds.
Display Mode: LED display
SpO2 Measuring Range: 0%~100%, (the resolution is 1%).
Accuracy: 70%~100%: ± 2%, Below 70% unspecified.
PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm)
Accuracy: ± 2bpm or ± 2% (select larger)
Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ± 4%, pulse rate error is ± 2 bpm or ± 2% (select larger).
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ± 1%.
Power Consumption: Less than 25mA
Voltage: DC 2.6V~3.6V
Power Supply: 1.5V (AAA size) alkaline batteries * 2
Battery working hour: The minimum continually work time is 24 hours, theoretical number is
56 hours.
Safety Type: Interior Battery, BF Type

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier